As soon as possible after Hemsec by SBUK SIP panels walls have been erected, a breathable membrane, e.g. TF200, should be fixed directly to the panels. External cladding should be installed over the breathable membrane.
The following are examples of external cladding for walls:
Tiles
Slate
Fixing
As soon as the tilers have finished, decorate the facia and fix the guttering prior to the scaffolding coming down
U–values (W/m2.K) for Hemsec Building System Walls with Various Thicknesses of Additional Insulation and Different Breathable Membranes.
The u–values detailed below are quoted in accordance with BS EN ISO 6946:1997 and BRE report (BR443:2006)
Thermal conductivity (λ–value) of the OSB/3 component of Hemsec by SBUK SIP panels should be taken as 0.13 W/m.K. The thermal conductivity of the insulation core of Hemsec by SBUK SIP panels is 0.028 W/m.K.
In addition to the excellent U–values that can be achieved by walls and roofs constructed using the, Hemsec by SBUK SIP panels the closed cell structure of the rigid urethane insulation core of the panels does not allow movement of air within them.
The insulation will not sag or physically deteriorate over time, as may be the case with other insulating materials.
Air leakage levels can be as good as 0.08 air changes per hour at normal pressures (approximately 1 m3/hour/m2 at 50 Pa). Standard results would be 3 air changes per hour. This is subject to the quality of the overall build.
The Hemsec SIPs panel comprises of BBA Approved 15mm Internal and 15mm External Oriented Strand Board (OSB) grade 3 facings. OSB/3 has a thermal conductivity value λ of 0.13 W/mK.
Manufactured to specification EN 13986 and EN 300:2006, OSB/3 comprises of strands of softwood bonded together using a formaldehyde free synthetic resin.
The OSB boards are responsibly sourced and comply to FSC and PEFC chain of custody requirements.
Further information and Certification can be obtained on request through Hemsec SIPs.
The core of Hemsec by SBUK SIP panels are a closed cell Polyurethane rigid foam system with zero Ozone Depletion Potential (ODP) supplied by BASF
Polyurethanes Europe.
The PUR core is CFC and HCFC free providing a < 5 value for GWP, as specified by various regulatory bodies.
Hemsec by SBUK SIP panels are available in the following standard size(s):
ALL PROJECTS ARE CUT BESPOKE TO SUIT YOUR DESIGN.
Assessed to be acceptable in relation to the intended use of the building and any limitations regarding climatic zones
Hemsec SIPs are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with ISO9001:2008 standard, ensuring long-term reliability and service life. Hemsec BBA Certificate
The panels will have comparable durability to that of OSB/3 to BS EN 300 : 2006, therefore, provided the installation remains weathertight and damp-proof; a life of at least 60 years may be expected. The long life expectancy of our product will reduce energy consumption of a building over its’ lifespan.
The rigid urethane insulation core is resistant to dilute acids, alkalis, mineral oil and petrol. It is not resistant to some solvent–based adhesive systems, particularly those containing methyl ethyl ketone.
Adhesives containing such solvents should not be used in association with Hemsec by SBUK Building System.
Hemsec Building System components, which have been in contact with harsh solvents, petrol, mineral oil or acids, or components that have been damaged in any way should not be used.
The rigid urethane insulation core and facings used in the manufacture of Hemsec by SBUK SIP panels resist attack by mould and microbial growth and do not provide any food value to vermin.
The permissible vertical load resistance for Hemsec by SBUK SIP panels is sufficient for the System’s use as loadbearing partitions, separating walls, the inner leaf of external walls and pitched roofs in dwellings up to four storeys high.
Weighted apparent sound reduction index for separating walls achieves a sound reduction of (Rw) of 44 dB
Weighted apparent sound reduction index for all other walls achieves a sound reduction of (Rw) of 37 dB
Panel Internal and External OSB and CPB facings have Class 3 surface spread of flame to BS476: Part 7:
1987. When Hemsec SIPs are used as part of a through-wall build up they pass the requirements of BS476 Part
21 fire resistance of load bearing walls and have achieved up to 75 minutes fire rating. Non-Load bearing walls
can achieve up to a 90 minute fire rating (BS476 Part 22:1987).
If our frequently asked questions do not answer your enquiry, please do get in touch with us so that we can assist you further. Contact Us
You may also find relevant information on our group site at www.sbukgroup.co.uk